Portfolio page

Project details

osynox atomizer2
flame profile

An oil fired power station boiler was fitted with a set of Osynox atomizers to reduce NOx emissions below the European directive of 450 mg/Nm3 from an operating level of around 600 mg/Nm3 without the need to change burner air registers or any other part of the combustion system.

This was achieved without compromising boiler load or particulate emissions which were maintained at or below 50 mg/Nm3.


Typical Results:
Boiler Capacity:No Burners :Fuel Type: N2 in Fuel: NOx (mg/Nm3):
261 T/H8HFO0.37%590 (Original Tips)
261 T/H8HFO0.37%365 (Osynox Tips)